Product highlights
Intelligent temperature sensing
The 68℃ temperature sensing element responds precisely and automatically releases the fire extinguishing agent when a fire occurs.
Multiple safety guarantees
An optional safety valve device is available to prevent the risk of system overpressure.
Precision thread design
Multi specification thread interfaces for import and export to ensure system sealing.
Wide pressure working range
2.2-2.4MPa working pressure, suitable for the requirements of various fire extinguishing systems.
Durable structure
Made of high quality metal materials, it is corrosion resistant, heat resistant and has a long service life.

Technical parameters
| Project | Specification |
| Imported thread | M30x1. 5 |
| Export thread | M12x1. 5 |
| Pressure gauge thread | M10x1-12.5 |
| Immersion tube thread | M16x1. 5 |
| Range of working pressure | 2.2-2.4 MPa |
| Trigger temperature | 68 ℃ |
| Applicable fire extinguishing agent | A variety of fire extinguishing agents such as dry powder and gas |
| Applicable ambient temperature | - 20 ℃ ~ + 60 ℃ |
| Material | Brass/Stainless steel (optional) |
Product structure

1.Main valve body:
Precisely processed integrated structure to ensure system sealing.
2.Temperature sensing element:
68℃ low-melting-point alloy, with rapid and reliable response.
3.Pressure interface:
Standard pressure gauge interface for convenient system monitoring.
4.Immersion pipe connection:
Special M16x1.5 thread to ensure smooth delivery of fire extinguishing agent.
Scope of application

Applicable places
- Power distribution room
- Communication machine room
- Warehouse storage area
- Industrial production line
- Kitchen back kitchen
- Vehicle engine compartment
Applicable fire extinguishing system
- Suspended dry powder fire extinguishing device
- Gas automatic fire extinguishing system
- Local application of fire extinguishing systems

Installation Instructions
- Select an appropriate installation location based on system requirements, usually at the top of the protected area.
- Use a dedicated tool to connect the valve to the fire extinguishing agent container, ensuring that the inlet thread (M30x1.5) is well sealed.
- Connect the immersion tube to the M16x1.5 threaded interface.
- Install the pressure gauge to the M10x1-12.5 interface (if necessary).
- Connect the release pipeline to the M12x1.5 outlet thread.
- After installation is completed, conduct a pressure test to ensure there is no leakage.
Precautions for Use
Please confirm that the working pressure does not exceed 2.4MPa before installation.
Regularly check the status of the temperature sensing element. It is recommended to do so every six months.
When maintaining the system, the pressure should be released first.
The sealing test must be reconducted after the fire extinguishing agent is replaced.
The safety valve assembly needs to be tested for its functional effectiveness regularly.
Maintenance and upkeep
Monthly inspection
Check whether the appearance of the valve is corroded or damaged.
Confirm that the reading of the pressure gauge is within the normal range.
Annual maintenance
Test the response performance of the temperature sensing element.
Check the sealing performance of all threaded connections.
Clean the surface and internal channels of the valve.
Five year major overhaul
It is recommended to replace all the seals.
Conduct a comprehensive inspection of the valve performance.
Replace the temperature sensing component when necessary.
FAQ
Is the trigger temperature of this model fixed at 68℃? Can other temperatures be customized?
The temperature sensing element of the standard product is 68℃, which is suitable for most fire protection scenarios. If other trigger temperatures (such as 93℃ for high temperature environments) are required, customized services can be provided. Please note your requirements when placing an order.
What types of fire extinguishing agents is it applicable to?
It is applicable to common fire extinguishing agents such as dry powder (Class ABC), carbon dioxide (CO₂), heptafluoropropane (HFC-227ea), etc. It is not suitable for water based fire extinguishing agents (which can easily cause valve corrosion).
How to determine if the temperature sensing element has failed?
It is recommended to have a functional check every six months. A hot air gun or hot water (close to 68℃) can be used to test whether the temperature sensing element melts normally and trigger the valve. If there is no response, the temperature sensing component needs to be replaced.
Is the product suitable for outdoor environments?
The standard version is suitable for indoor environments. If it needs to be used outdoors, it is recommended to choose the stainless steel version and add a rain cover to prevent the temperature sensing element from getting damp or triggering by error.
If you have any questions, please contact our team and we will provide you with professional technical support and solutions.
This product strictly adheres to the manufacturing standards of fire protection equipment and has passed multiple quality certifications. It is a reliable choice for your fire safety.
Order now and upgrade your security protection with an intelligent solution! 🔥🚒
Hot Tags: automatic fire extinguisher valve, China, manufacturers, suppliers, factory, custom, price, for sale