Product parameters
- Material: High strength stainless steel (specific model can be provided according to customer requirements)
- Surface treatment: Precision polishing / Corrosion resistant coating (optional)
- Working pressure range: 2.2 - 2.4 MPa (The standard design can withstand higher pressure)
- Blasting pressure: ≥ 8.0 MPa (with a high safety factor)
- Temperature range: -30°C to +60°C (stable performance in extreme environments)
Professional threaded interface
Imported thread: M30x1.5 (standard industrial interface)
Exterior thread: M16x1.5 (suitable for most nozzles)
Pressure gauge connection thread: M10x1 - 12.5 (for system monitoring)
Inlet pipe thread: M16x1.5 (optimized for liquid transmission)
Safety features
Built in safety valve: Automatic pressure relief protection (adjustable design)
Double-sealing system: Main O-ring + Auxiliary gasket sealing
Anti-misoperation design: Special structure to prevent accidental opening
CE certification: Compliant with European fire safety standards such as EN3-7


Applicable scenarios
Commercial buildings: office buildings, shopping malls, hotels fire extinguishing systems
Industrial facilities: chemical plants, power stations, warehouses fire protection equipment
Transportation means: Ships, special vehicles fire extinguishing devices
Special environments: Corrosive environments such as offshore platforms and underground facilities
Compatible fire extinguishing agent types
Dry powder extinguishing agent (ABC/BC type)
Clean gas fire extinguishing agent (such as FM200)
Carbon dioxide fire extinguishing system
Water based fire extinguishing agent (including foam)
Core advantages
Outstanding material performance
High corrosion resistance: Stainless steel material resists chemical agent erosion
High durability: Tested to withstand ≥ 10,000 opening and closing cycles
Health and Environmental Protection: No heavy metals are released, in compliance with the RoHS directive
Precision engineering design
Fluid optimization design: Reducing pressure loss through internal channels
Quick response: The special valve core structure ensures full opening instantly
Modular design: Facilitates maintenance and component replacement
Safe and reliable guarantee
Multiple protections: Safety valve + Overpressure protection dual mechanism
Visual indication: Optional pressure gauge interface for real-time monitoring
Leak-proof design: Passed a 1.5 times working pressure test
Certification and Testing
International Certifications: CE, ISO9001 Quality Management System
Pressure test: Each product undergoes a separate airtightness test
Installation and Maintenance
Installation Guide
- Check that all threaded interfaces are clean and undamaged
- Use special sealing tape or sealant (not included in the product)
- Fasten each connection part according to the standard torque value
- After installation, conduct a pressure test (recommendation: 1.5 times the working pressure)
Maintenance suggestion
- Check the external condition of the valve every month
- Test the operational flexibility on a quarterly basis
- Carry out professional inspections and maintenance every year
- It is recommended to replace the sealing components every five years
Purchase Information
Packaging Specifications
Single piece shockproof plastic bag packaging
Standard cardboard boxes (optional wooden box for export packaging)
Ordering options
Standard model: Configured as shown on the page
Customized service: Special threads and pressure range can be customized
Bulk discount: Enjoy tiered price discounts when purchasing multiple items
Logistics services
Global express delivery (DHL/FedEx)
Large scale orders by sea or air transportation
Provide complete export customs declaration documents
FAQ
01.Are there different sizes of interfaces available for selection?
02.What should be noted when installing a pressure gauge?
- Use the appropriate sealing material
- Do not over tighten. The recommended torque is 15-20 N·m.
- After installation, a static pressure test should be conducted.
03.How to handle the situation when is difficult to open?
- Check if the handle is deformed or damaged
- Confirm whether the system pressure has been completely released.
- Proper lubrication should be applied to the stem area (using a dedicated silicon based lubricant)
04.Why does the safety valve frequently release pressure?
- The system pressure has exceeded the set value (check the filling pressure)
- Safety valve spring is fatigued (needs replacement)
- The valve seat sealing surface is damaged (requires professional repair)
- The change in environmental temperature leads to fluctuations in pressure (which is a normal phenomenon)
05.What should be noted when using in a low-temperature environment?
- Confirm that the sealing material is suitable for low temperatures (standard product is applicable up to -30°C)
- Check if the valve is frozen before operation
- Consider installing insulation measures
- Prevent the failure of the seal due to rapid temperature changes
06.Is it compatible with all types of fire extinguishing agents?
This stainless steel extinguisher valve integrates the latest technologies of modern fire fighting equipment and strict quality standards, providing reliable protection for your property safety. This product is recommended by professional fire engineers. Welcome to inquire about the wholesale price and customization services!
Hot Tags: ce stainless steel fire extinguisher valve, China, manufacturers, suppliers, factory, custom, price, for sale