XH001-033A - Extinguisher for Electrical Risks
| Parameter | Specification |
|---|---|
| Product | Extinguisher for Electrical |
| Product Code | XH001-033A |
| Agent | ABC Powder |
| Agent Capacity | 2.0 kg |
| Fire Rating | 13A, 55B |
| Type of Fire | A, B, C, E |
| Cylinder Diameter | 109.5 mm |
| Overall Height | 400 mm |
| Overall Weight | 3.3 kg |
| Discharge Time | 8–12 seconds |
| Working Pressure | 14 bar |
| Test Pressure | 25 bar |
| Packing Detail | 130 × 165 × 415 mm |
| Manufacturing Standard | BS EN3 |
| CE Marking | CE0036 |
| Warranty | 5 years |
Designed for Electrical Fire Risks
Electrical equipment introduces a different fire-protection requirement from ordinary combustible materials.
A fire may originate from:
- Overheated electrical components
- Short circuits
- Damaged wiring
- Electrical control cabinets
- Motors and generators
- Switchboards
- Distribution equipment
- Power supplies
- Industrial machinery
- Electronic equipment
The extinguisher must therefore be selected according to both the electrical hazard and the surrounding combustible materials.
This ABC powder model is designed for suitable electrical fire applications while also providing Class A and Class B fire coverage.
Insulating Dry Powder for Electrical Applications
One of the key characteristics of this extinguisher is its dry powder agent.
The supplied product information specifies that the powder has insulating properties and does not conduct electricity.
When discharged onto a suitable electrical fire, the powder can:
- Reach the combustion area.
- Interfere with the combustion reaction.
- Suppress the flame.
- Reduce the continuation of combustion.
This makes dry powder an option for certain energized electrical fire risks where the appropriate fire rating and operating conditions are met.
Electrical power should be isolated whenever this can be done safely.
ABC Powder for More Than Electrical Equipment
Although the product is positioned for electrical fire protection, its ABC powder formulation provides broader fire coverage.
Type A - Solid Combustibles
Suitable for applicable fires involving ordinary combustible materials such as:
- Paper
- Wood
- Cardboard
- Textiles
- Other solid combustible materials
Type B - Flammable Liquids
The extinguisher can be used for suitable fires involving flammable liquids, depending on the fire classification and application requirements.
Type C - Flammable Gases
ABC powder can be used for suitable flammable-gas fire risks.
Type E - Electrical Equipment
The product is specified for electrical fire applications where the extinguisher's rating and local requirements permit its use.
13A, 55B Fire Rating
The 13A, 55B rating provides a measurable reference for the extinguisher's tested fire-extinguishing performance.
For procurement teams, this is more useful than simply comparing agent weight.
When selecting extinguishers for electrical facilities, the following specifications should be evaluated together:
| Selection Factor | This Model |
|---|---|
| Agent | ABC Powder |
| Agent Capacity | 2.0 kg |
| Class A Rating | 13A |
| Class B Rating | 55B |
| Electrical Application | Type E |
| Discharge Time | 8–12 s |
| Working Pressure | 14 bar |
| Test Pressure | 25 bar |
The required rating should always be checked against the applicable fire-protection standard and site risk assessment.
Electronic Leak Detection During Production
The supplied product information states that the extinguisher is tested by electronic leak detection.
Leak control is particularly important for pressurized fire extinguishers because loss of pressure can affect the extinguisher's readiness for emergency use.
Electronic detection provides a production-stage method for checking the cylinder or assembled extinguisher for leakage before shipment.
For bulk purchasers, quality-control procedures such as pre-production samples and final inspection can also be incorporated into the supply process.
2.0 kg Compact Electrical Fire Extinguisher
The 2.0 kg configuration provides a balance between agent capacity and portability.
With an overall height of approximately 400 mm and cylinder diameter of 109.5 mm, the extinguisher can be positioned at designated fire-protection points without requiring a large installation footprint.
The specified overall weight is approximately 3.3 kg.
This makes the model practical for locations where personnel may need to remove the extinguisher quickly and carry it to an incipient fire.
8–12 Second Discharge Window
The specified discharge time is 8–12 seconds.
Because the available agent is discharged over a limited period, the operator needs to position the extinguisher correctly before activation.
For a suitable electrical fire:
- Approach only when it is safe.
- Keep a clear escape route.
- Aim toward the base or appropriate area of the fire.
- Operate the extinguisher according to the manufacturer's instructions.
- Sweep the discharge across the affected area where appropriate.
- Stop and evacuate if the fire grows beyond portable-extinguisher control.
A portable extinguisher should be regarded as first-response equipment, not as a substitute for a fixed fire-suppression system in high-risk electrical installations.
Where to Install an Electrical Fire Extinguisher
The extinguisher can be considered for locations where electrical equipment represents a recognized fire hazard.
For areas containing distribution equipment, control panels and electrical installations.
Suitable for selected industrial environments where electrical control systems are installed alongside mechanical equipment.
Useful where electrical tools, machinery, wiring and combustible materials may be present in the same work area.
Can be positioned at designated fire-extinguisher points in offices and commercial facilities where electrical equipment is a primary fire risk.
Suitable for selected production and utility areas after the fire risk and required extinguisher classification have been assessed.
Can be incorporated into fire-protection layouts for rooms containing motors, control equipment, power supplies and related electrical installations.
Electrical Fire Protection Without Relying on Water
Water-based extinguishing equipment is not automatically suitable for energized electrical equipment.
For this reason, the extinguishing agent becomes an important part of electrical fire-protection planning.
ABC dry powder provides an alternative for suitable electrical fire scenarios while also covering Class A and Class B hazards.
However, the correct extinguisher should always be selected according to:
- Voltage and electrical equipment type
- Fire classification
- Applicable standards
- Installation environment
- Manufacturer's instructions
- Local fire-safety requirements
14 Bar Working Pressure & 25 Bar Test Pressure
This model is specified with:
Working Pressure: 14 bar
Test Pressure: 25 bar
The pressure specifications provide buyers with key information for evaluating the cylinder and pressure system.
For distributors and project purchasers, pressure data should be reviewed together with certification, cylinder material, valve configuration and applicable inspection requirements rather than treated as an isolated specification.
Manufactured to BS EN3
The extinguisher is specified as:
- Manufactured to BS EN3
- CE Marked to CE0036
For international projects, certification should be confirmed against the exact product configuration and the regulatory requirements of the destination market.
The manufacturer can also provide relevant product documentation for qualified orders.
5-Year Manufacturer's Warranty
The extinguisher comes with a 5-year manufacturer's warranty, subject to the required servicing conditions.
The warranty does not cover defects or damage resulting from:
- Accident
- Misuse
- Neglect
- Improper operation
- Failure to follow servicing requirements
The supplied warranty conditions specify servicing in accordance with BS 5306 Part 3.
Quality Control for Bulk Orders
For distributors and fire-protection contractors, consistency between individual extinguishers is important when purchasing in volume.
The supplied production process includes:
- Pre-production sample confirmation
- Production inspection
- Electronic leak detection
- Final inspection before shipment
- Certification documentation
- Export packaging
This provides a structured quality-control process for bulk electrical fire-extinguisher orders.
Technical Data Sheet
| Item | Specification |
|---|---|
| Model | XH001-033A |
| Agent | ABC Powder |
| Capacity | 2.0 kg |
| Fire Rating | 13A, 55B |
| Fire Type | A, B, C, E |
| Cylinder Diameter | 109.5 mm |
| Overall Height | 400 mm |
| Overall Weight | 3.3 kg |
| Discharge Time | 8–12 seconds |
| Working Pressure | 14 bar |
| Test Pressure | 25 bar |
| Leak Detection | Electronic Leak Detection |
| Packing Size | 130 × 165 × 415 mm |
| Standard | BS EN3 |
| CE Marking | CE0036 |
| Warranty | 5 years |
Frequently Asked Questions (FAQ)
1. What type of extinguisher is this?
It is a 2.0 kg ABC dry powder fire extinguisher designed for suitable electrical and general fire risks.
2. Can this extinguisher be used on energized electrical equipment?
The product is specified for Type E electrical fire applications and uses an insulating dry powder agent. Electrical power should be disconnected whenever this can be done safely.
3. What is the fire rating?
The fire rating is 13A, 55B.
4. What extinguishing agent does it use?
The extinguisher uses ABC Powder.
5. What is the discharge time?
The specified discharge time is approximately 8–12 seconds.
6. What is the operating pressure?
The working pressure is 14 bar, with a 25 bar test pressure.
7. What is the weight of the extinguisher?
The specified overall weight is approximately 3.3 kg.
8. What is the operating temperature?
The supplied product information does not specify an operating-temperature range for this model, so the applicable temperature requirement should be confirmed with the manufacturer for the intended installation environment.
9. How is leakage checked?
The product information specifies electronic leak detection as part of the testing process.
10. Does it meet BS EN3 requirements?
The supplied specification states that the extinguisher is manufactured to BS EN3 and CE marked to CE0036.
11. What is the warranty period?
The manufacturer's warranty is 5 years, subject to the applicable servicing requirements.
12. Can you supply other fire-protection products?
Yes. The supplied product range includes fire extinguishers, automatic fire suppression systems, fire extinguisher accessories and other fire-fighting equipment.
Hot Tags: extinguisher for electrical, China, manufacturers, suppliers, factory, custom, price, for sale, 2kg Dry Powder Fire Extinguisher, Automatic ABC Dry Powder Fire Extinguisher, Chemical Dry Powder Fire Extinguisher, Dry Powder Car Fire Extinguisher, Extinguisher For Flammable Liquids, Natural Fire Extinguisher