Key Product Specifications
| Item | Specification |
|---|---|
| Product | Portable Dry Powder Fire Extinguisher |
| Product Code | XH001-041A |
| Agent Type | Dry Powder |
| Agent Charge | 2.0 kg |
| Cylinder Capacity | 2.50 L |
| Shell Diameter | 110 mm |
| Overall Height | 375 mm |
| Full Weight | 3.52 kg |
| Working Pressure | 14 bar |
| Cylinder Test Pressure | 27 bar |
| Operating Temperature | -30°C to +60°C |
| Packing | 360 × 250 × 400 mm / 6 pcs |

Designed Around Common First-Response Fire Risks
A portable extinguisher is normally used during the initial stage of a fire, before the fire develops beyond the capability of portable firefighting equipment.
Dry powder is particularly suitable for fire risks involving:
| Fire Risk | Typical Application |
|---|---|
| Flammable liquids | Fuel, oils and other combustible liquid incidents |
| Flammable gases | Gas-related fire during the initial stage |
| Energized electrical equipment | Electrical equipment where the power source cannot immediately be isolated |
| General combustible materials | Selected applications where dry powder is specified by the fire-protection plan |
The exact extinguisher class and agent selection should always follow the applicable fire-risk assessment and local fire-safety requirements.
Not intended for metal fires: standard dry powder extinguishers of this type should not be selected for fires involving combustible metals unless the powder is specifically rated for that application.
2 kg Dry Powder Charge in a Portable Format
The 2.0 kg agent charge is configured for situations where the extinguisher needs to be manually carried and rapidly deployed.
The cylinder measures approximately 375 mm in height with a 110 mm shell diameter, providing a compact form factor for wall-mounted or designated extinguisher points.
At a full weight of approximately 3.52 kg, it can be incorporated into distributed fire-protection layouts without requiring the larger footprint associated with high-capacity extinguishers.
This configuration is particularly useful when multiple extinguishers need to be positioned throughout a facility according to the identified fire risks.
14 Bar Working Pressure for Consistent Discharge
The extinguisher is specified with a 14 bar working pressure and a 27 bar cylinder test pressure.
The pressure specification is important when evaluating an extinguisher for industrial or commercial installation because it relates directly to the pressure conditions under which the cylinder and discharge system are designed to operate.
For purchasing and installation, the extinguisher should be stored, inspected and maintained according to the manufacturer's instructions and the applicable local requirements.
Operating Temperature: -30°C to +60°C
The specified operating temperature range is:
-30°C to +60°C
This allows the extinguisher to be considered for a broad range of indoor and outdoor environments, subject to the installation conditions and applicable fire-protection requirements.
For outdoor installation, the extinguisher should be protected from conditions that could damage the cylinder, valve, operating mechanism or identification markings.
For cold-storage, high-temperature industrial or exposed outdoor applications, the actual installation environment should be checked before selection.
How to Use a Dry Powder Fire Extinguisher
When a dry powder extinguisher is appropriate for the identified fire class, correct discharge positioning is important.
For a stationary liquid fire
Aim the discharge toward the base of the flame, rather than the upper part of the flame.
The objective is to direct the extinguishing agent into the area where combustion is taking place.
For a flowing liquid fire
When burning liquid is flowing, the operator should work from a safe position and direct the discharge toward the root of the flame, moving the discharge across the affected area until the visible flames are extinguished.
For electrical equipment
Where electrical equipment is involved, the extinguisher must be suitable for energized electrical equipment and the operator should maintain the safe distance specified for the product. Where possible, isolate the electrical supply before firefighting.
Important
Portable extinguishers are intended for incipient-stage fires. If the fire is growing rapidly, producing heavy smoke, spreading beyond the immediate area or cannot be controlled safely, personnel should evacuate and follow the site's emergency procedure.
Built for Fire-Extinguisher Distribution Systems
The value of a portable extinguisher is not only determined by the cylinder itself. Its location, accessibility, inspection status and suitability for the site's fire hazards are equally important.
This 2 kg configuration can be incorporated into fire-protection layouts for areas such as:
Workshops & Maintenance Areas
Suitable for locations where lubricants, fuels, machinery and electrical equipment may create multiple fire risks.
Warehouses
Can be positioned at designated access points and other locations identified through the site's fire-risk assessment.
Vehicle & Equipment Service Areas
Dry powder extinguishers can be considered where fuel, oil and electrical fire risks are present.
Industrial Facilities
Useful as portable first-response equipment around production areas, plant rooms and utility areas where the selected extinguisher class matches the identified hazards.
Commercial & Building Facilities
Can be incorporated into distributed portable fire-extinguisher installations where permitted by local fire-safety requirements.
Designed for Procurement and Installation
For distributors, contractors and facility operators, selecting an extinguisher involves more than choosing the agent type.
The following specifications should be confirmed before purchase:
| Procurement Item | What to Confirm |
|---|---|
| Fire class | Match the extinguisher to the actual fire hazards |
| Agent charge | 2.0 kg for this configuration |
| Dimensions | 110 mm diameter × 375 mm height |
| Full weight | Approx. 3.52 kg |
| Working pressure | 14 bar |
| Test pressure | 27 bar |
| Temperature | -30°C to +60°C |
| Certification | Confirm required market certification |
| Installation | Wall-mounted or designated extinguisher location |
| Maintenance | Follow applicable inspection and servicing requirements |
| Branding | OEM/private-label requirements can be discussed |
| Packaging | 6 pcs per 360 × 250 × 400 mm package |
Compliance and Certification
This model is specified as manufactured to BS EN3 and CE marked to CE0036, according to the supplied product information.
For projects requiring regulatory compliance, buyers should confirm that the exact model, manufacturing configuration, certification documentation and intended market requirements correspond to the applicable installation standard.
For maintenance and servicing, the supplied product information specifies servicing in accordance with BS 5306 Part 3 for the manufacturer's warranty conditions.
5-Year Manufacturer's Warranty
Every extinguisher is supplied with a 5-year manufacturer's warranty, subject to the stated warranty conditions and required servicing.
The warranty does not cover defects or damage resulting from:
- Accident
- Misuse
- Neglect
- Improper handling
- Failure to follow applicable servicing requirements
For bulk projects, distributors and facility operators should establish an inspection and servicing schedule that complies with the applicable local fire-safety requirements.
OEM & Private Label Options
For distributors, fire-protection suppliers and project contractors, portable extinguishers may need to match an existing product range or customer brand.
Custom services can include:
- Customer logo printing
- Product identification
- Label customization
- Packaging requirements
- Bulk-order configuration
- Product documentation
- Project-specific specifications
Before placing a customized order, the required market certification and labeling requirements should be confirmed so that the final configuration remains suitable for the intended market.
Why Specify This 2 kg Configuration?
| Buyer Requirement | Corresponding Configuration |
|---|---|
| Need a portable extinguisher | 3.52 kg full weight |
| Need compact installation | 110 mm shell diameter |
| Need a 2 kg agent charge | 2.0 kg dry powder |
| Need defined pressure specifications | 14 bar working / 27 bar test pressure |
| Need operation across varying temperatures | -30°C to +60°C |
| Need recognized product requirements | BS EN3 / CE0036 as specified |
| Need long-term manufacturer support | 5-year manufacturer's warranty |
| Need private-label supply | OEM logo and labeling available |
| Need bulk distribution | 6 pcs per package |
Portable Dry Powder Fire Extinguisher - Technical Data
| Parameter | Value |
|---|---|
| Model | XH001-041A |
| Extinguishing Agent | Dry Powder |
| Agent Weight | 2.0 kg |
| Cylinder Capacity | 2.50 L |
| Cylinder Diameter | 110 mm |
| Height | 375 mm |
| Full Weight | 3.52 kg |
| Working Pressure | 14 bar |
| Test Pressure | 27 bar |
| Operating Temperature | -30°C to +60°C |
| Packing Quantity | 6 pcs/carton |
| Packing Dimensions | 360 × 250 × 400 mm |
| Manufacturing Standard | BS EN3 |
| CE Marking | CE0036 |
| Warranty | 5 years, subject to servicing requirements |
FAQ
1. What fires is this dry powder extinguisher suitable for?
It is intended for suitable first-response fire risks involving flammable liquids, flammable gases and energized electrical equipment, with the exact application depending on the fire classification and local requirements.
2. Can it be used for metal fires?
No. A standard dry powder extinguisher of this configuration should not be used for combustible-metal fires unless it is specifically designed and certified for that fire class.
3. What is the agent charge?
The extinguisher contains a 2.0 kg dry powder charge and has a nominal cylinder capacity of 2.50 L.
4. What is the working pressure?
The specified working pressure is 14 bar, while the cylinder test pressure is 27 bar.
5. What is the operating temperature range?
The specified operating temperature is -30°C to +60°C.
6. Does the product have certification?
According to the supplied specifications, the product is manufactured to BS EN3 and CE marked to CE0036. Certification documents should be confirmed for the specific order and destination market.
7. How long is the manufacturer's warranty?
The product is supplied with a 5-year manufacturer's warranty, subject to the stated servicing requirements. The supplied warranty conditions exclude damage caused by accident, misuse or neglect.
8. Can you print our company logo?
Yes. OEM/private-label customization, including customer logo printing, can be discussed for qualified orders.
9. What is the minimum order quantity?
The supplied product information lists an MOQ of 1,000 pieces.
10. How is the extinguisher packaged?
The listed packing specification is 6 pieces per package, with packing dimensions of approximately 360 × 250 × 400 mm.
11. How should the extinguisher be maintained?
Inspection and servicing should follow the manufacturer's instructions and the applicable fire-safety requirements in the installation market. The supplied warranty information specifically refers to servicing requirements under BS 5306 Part 3.
12. Is this extinguisher suitable for every fire risk?
No. Extinguisher selection should be based on the specific fire hazards at the installation site. Dry powder is not a universal replacement for water, foam, CO₂ or specialized extinguishing agents.
Hot Tags: portable dry powder fire extinguisher, China, manufacturers, suppliers, factory, custom, price, for sale, Automatic ABC Dry Powder Fire Extinguisher, Automatic Fire Extinguisher, Ce Fire Extinguisher, Clean Agent Fire Extinguishers, Fire Extinguisher For Office, Fire Extinguisher For Petrol