CO2 Fire Extinguisher for Car

CO2 Fire Extinguisher for Car

Clean CO₂ Fire Protection for Vehicle Electrical and Flammable Liquid Risks
The CO2 Fire Extinguisher for Car is a compact high-pressure fire extinguisher designed for vehicle and equipment fire risks where a clean extinguishing agent is preferred.
Carbon dioxide extinguishes fire primarily by reducing the oxygen concentration around the combustion zone. When discharged, liquid CO₂ rapidly expands into gas and absorbs heat from the surrounding area, helping suppress the fire without leaving powder or foam residues.
For vehicles, this makes CO₂ particularly suitable for selected electrical equipment and Class B fire risks, especially where post-fire cleanup and protection of sensitive components are important. The supplied configuration uses a 2.0 kg CO₂ charge, with an aluminum-alloy cylinder designed for high-pressure service.
Send Inquiry
Description
Technical Parameters

Key Specifications at a Glance

Parameter Specification
Product CO2 Fire Extinguisher for Car
Product Code XH001-054A
Extinguishing Agent Carbon Dioxide (CO₂)
CO₂ Charge 2.0 kg
Cylinder Capacity 3.0 L
Shell Diameter 105 mm
Height 480 mm
Extinguisher Weight 7.4 kg
Working Pressure 150 bar
Test Pressure 250 bar
Manufacturing Standard BS EN3
CE Marking CE0036
Warranty 5 years
Packing Size 120 × 120 × 510 mm / 170 × 130 × 620 mm

CO2 Fire Extinguisher for Car

Why CO₂ Is Suitable for Vehicle Fire Protection

Vehicles contain a combination of electrical circuits, batteries, wiring, control units, fuel and lubricants. The correct extinguisher therefore depends on the actual fire hazard.

CO₂ has several characteristics that make it useful for selected vehicle applications:

No Powder Residue

Unlike dry powder extinguishers, CO₂ does not discharge a layer of powder onto the protected equipment.

This can be beneficial when the fire involves:

  • Electrical control equipment
  • Wiring and electrical connections
  • Instrumentation
  • Electronic components
  • Sensitive vehicle equipment

Less residue can also simplify post-fire cleaning.

Non-Conductive Extinguishing Agent

CO₂ is electrically non-conductive, making it suitable for certain energized electrical fire situations when the extinguisher is correctly rated and used according to safety requirements.
The electrical supply should be isolated whenever this can be done safely.

Suitable for Selected Class B Fire Risks

CO₂ can be used for suitable Class B fires, including certain flammable-liquid fire risks.
For vehicle applications, the actual extinguisher selection should be based on the vehicle's fuel type, electrical system, fire classification and applicable regulations.

How a CO₂ Fire Extinguisher Suppresses Fire

CO₂ works differently from dry powder.

  1. Oxygen Displacement
    When carbon dioxide is discharged into the combustion area, it surrounds the burning material and reduces the concentration of oxygen available to support combustion.
  2. Rapid Gas Expansion
    CO₂ is stored under high pressure in liquid form. During discharge, it rapidly expands from liquid to gas.
  3. Heat Absorption
    The rapid expansion and vaporization absorb heat from the surrounding area, helping reduce the temperature of the fire zone.
  4. Clean Discharge
    After discharge, CO₂ does not leave the powder or foam residue associated with other extinguishing agents.
    This is one of the key reasons CO₂ is selected for certain electrical and equipment-related fire risks.

Aluminum Alloy Cylinder for High-Pressure CO₂

The extinguisher uses an aluminum alloy cylinder, providing a high-pressure vessel configuration while helping reduce the weight associated with some steel-cylinder designs.

The specified cylinder has:

  • 3.0 L nominal capacity
  • 105 mm shell diameter
  • 480 mm overall height
  • 150 bar working pressure
  • 250 bar test pressure

Because CO₂ extinguishers operate at significantly higher pressure than many dry powder extinguishers, cylinder integrity and pressure testing are critical considerations during procurement and maintenance.

2.0 kg CO₂ Charge

The extinguisher contains a 2.0 kg CO₂ charge.

The configuration provides a practical option for vehicle fire-protection applications where the extinguisher must be manually carried to the fire while maintaining sufficient extinguishing-agent capacity for the intended risk.

The actual number, size and placement of extinguishers required should be determined according to the vehicle type, fire-risk assessment and applicable regulations.

Applications for Vehicle and Mobile Equipment

The CO2 Fire Extinguisher for Car can be considered for selected applications involving electrical and Class B fire risks.

Passenger Vehicles

Suitable for selected vehicle electrical and small flammable-liquid fire risks where CO₂ is appropriate.

Commercial Vehicles

Can be considered for trucks, vans and other commercial vehicles with electrical equipment and relevant fire hazards.

Automotive Workshops

Useful where technicians work around vehicle electrical systems, control equipment and flammable liquids.

Vehicle Service Centers

Can be incorporated into fire-protection arrangements around maintenance and repair areas.

Construction & Mobile Equipment

For selected machinery and mobile equipment where electrical components create a fire risk.

Electrical Equipment Areas

The clean discharge characteristics of CO₂ make it suitable for certain electrical equipment applications beyond vehicles.

CO₂ Fire Extinguisher vs. Dry Powder Extinguisher

The two extinguishing agents serve different purposes.

Feature CO₂ Extinguisher Dry Powder Extinguisher
Extinguishing Agent Carbon dioxide Dry chemical powder
Discharge Residue No powder residue Powder residue remains
Electrical Fire Suitable for selected electrical risks Suitable for selected electrical risks
Class B Fire Suitable Suitable
Sensitive Equipment Advantage where clean discharge is required Powder may require extensive cleaning
Cylinder Pressure High Lower than CO₂ configuration
Typical Use Electrical equipment, selected Class B risks Broader range of first-response fire risks
Metal Fire Not suitable Standard model not suitable
Indoor Use Suitable with adequate ventilation and correct application Suitable according to fire classification

Important: CO₂ is not a universal replacement for dry powder or other extinguishing agents. Extinguisher selection should always correspond to the specific fire hazard.

Designed for Clean Fire Suppression

For vehicle owners and equipment operators, extinguishing the fire is only part of the consideration. The condition of the surrounding equipment after discharge can also matter.

CO₂ provides a clean extinguishing medium with no powder or foam contamination.

This can be particularly relevant around:

  • Electrical control units
  • Wiring systems
  • Instrument panels
  • Electronic equipment
  • Machinery controls
  • Workshop electrical installations

Where equipment is sensitive to contamination, the absence of powder residue can reduce the cleanup burden after discharge.

Operating Instructions

When a fire is detected, use the extinguisher only if the fire is at an early stage and it is safe to approach.

Step 1 - Assess the Fire

Confirm that the extinguisher is suitable for the fire type and that there is a safe escape route.

Step 2 - Approach from a Safe Position

Keep an appropriate distance from the fire and avoid positioning yourself where smoke or flames can block your escape.

Step 3 - Remove the Safety Pin

Release the safety mechanism according to the extinguisher design.

Step 4 - Direct the Horn Toward the Fire

Aim the discharge horn toward the base or appropriate area of the fire.
For electrical equipment, avoid unnecessary contact with the equipment and follow the product's safe operating instructions.

Step 5 - Operate the Handle

Press the operating handle to discharge the CO₂.

Step 6 - Continue Until the Fire Is Suppressed

Monitor the fire carefully after discharge. If the fire reignites or cannot be controlled, evacuate and follow the emergency response procedure.

Never touch the CO₂ discharge horn during operation, as the rapid expansion of CO₂ can make the horn extremely cold.

Safety Considerations for Vehicle Use

CO₂ extinguishers require specific handling because the extinguishing agent is stored at high pressure and CO₂ can displace oxygen.

For vehicle applications:

  • Keep the extinguisher securely mounted or stored in its designated position.
  • Prevent movement of the cylinder during driving.
  • Inspect the extinguisher regularly.
  • Keep the discharge horn and operating mechanism accessible.
  • Do not expose the cylinder to excessive heat.
  • Do not use the extinguisher in an enclosed space without considering CO₂ accumulation.
  • Evacuate the area if the fire cannot be controlled immediately.
  • Follow local fire-safety and vehicle-equipment regulations.

150 Bar Working Pressure

The specified working pressure is 150 bar, while the cylinder test pressure is 250 bar.
This high-pressure specification distinguishes CO₂ extinguishers from many conventional dry powder models.

For procurement, buyers should pay particular attention to:

  • Cylinder material
  • Pressure rating
  • Valve assembly
  • Test requirements
  • Certification
  • Manufacturing traceability
  • Inspection and servicing requirements

The supplied product specification should be checked against the requirements of the destination market before bulk purchase.

BS EN3 Manufactured & CE Marked

The product is specified as:
Manufactured to BS EN3
CE Marked to CE0036

For distributors, importers and project purchasers, certification should be verified against the exact product model and applicable market requirements before ordering.

The product documentation can also be matched with project-specific certification and labeling requirements.

5-Year Manufacturer's Warranty

The CO2 Fire Extinguisher is supplied with a 5-year manufacturer's warranty, subject to the specified servicing conditions.

The warranty does not cover defects or damage caused by:

  • Accident
  • Misuse
  • Neglect
  • Improper handling
  • Failure to follow required servicing procedures

The supplied warranty conditions require servicing in accordance with the applicable requirements of BS 5306 Part 3.

OEM & Bulk Supply

For automotive-equipment distributors, fire-protection suppliers and vehicle-equipment projects, customized supply can be arranged according to order requirements.

Available service options can include:

  • Customer logo
  • Private-label packaging
  • Product labeling
  • Customized documentation
  • Bulk orders
  • Project-based supply
  • Export packaging

For customized products, certification and labeling requirements should be confirmed according to the destination market before production.

Technical Data

Item Details
Model XH001-054A
Extinguishing Agent CO₂
CO₂ Weight 2.0 kg
Cylinder Capacity 3.0 L
Shell Diameter 105 mm
Height 480 mm
Total Extinguisher Weight 7.4 kg
Working Pressure 150 bar
Test Pressure 250 bar
Standard BS EN3
CE Mark CE0036
Warranty 5 years
Packing Size 120 × 120 × 510 mm / 170 × 130 × 620 mm

Note: Overall dimensions and extinguisher weight may vary slightly depending on the supplied cylinder dimensions and cylinder mass.

FAQ

1. What type of fire is a CO₂ extinguisher suitable for?

CO₂ extinguishers are commonly selected for electrical fire risks and suitable Class B fires, subject to the specific fire classification and local requirements.

2. Why use CO₂ for a car?

Vehicles contain electrical systems and electronic components where a clean extinguishing agent can be advantageous. CO₂ does not leave powder residue after discharge.

3. Does CO₂ damage electrical equipment?

CO₂ itself does not leave the powder or foam residue associated with other extinguishing agents. However, fire, heat and thermal shock can still damage electrical equipment, so CO₂ should not be considered a guarantee that equipment will remain undamaged.

4. How much CO₂ does this model contain?

The specified CO₂ charge is 2.0 kg.

5. What is the pressure of this CO₂ extinguisher?

The specified working pressure is 150 bar, with a 250 bar test pressure.

6. Is the cylinder made from aluminum?

Yes. The supplied product information specifies an aluminum alloy CO₂ extinguisher cylinder.

7. Does a CO₂ extinguisher leave residue?

CO₂ does not leave powder or foam residue after discharge, which is one of its advantages for suitable electrical and equipment-related applications.

8. Can it be used for fuel fires?

CO₂ can be used for suitable Class B fire risks, but the specific fire situation and extinguisher rating must be considered before use.

9. Can it be used for metal fires?

No. This standard CO₂ extinguisher is not intended for combustible-metal fires.

10. Does it have CE certification?

The supplied product information states that the extinguisher is CE marked to CE0036 and manufactured to BS EN3.

11. What is the warranty period?

The manufacturer provides a 5-year warranty, subject to required servicing and the stated warranty conditions.

12. Can you provide OEM service?

Yes. Customer logos, labels, packaging and other private-label requirements can be discussed for bulk orders.

 

 

Hot Tags: co2 fire extinguisher for car, China, manufacturers, suppliers, factory, custom, price, for sale, 5kg Co2 Fire Extinguisher, Co2 Extinguisher, Co2 Fire Extinguisher, Liquid Co2 Fire Extinguisher, Portable Co2 Fire Extinguisher, Small Fire Extinguisher For Home

Send Inquiry
Send Inquiry