Dry barrel design eliminates darnage to the hydrant caused by freezing or corrosion of the upper part. Breakway design to prevent accidents to the hydrants,where only the upper of the flange will be broken upon impact. Extemally sandblasted for smooth finish, painted red with eletrostatic powder coating on the section above ground and double  coated with black bituminous paint on the section below the ground. Barrel length extension kit in different lengths is available on request.
Send Inquiry
Description
Technical Parameters

 

20240716153225111

 

What Is 3 Way Dry Barrel Outdoor Underground Hydrant

A 3-way dry barrel outdoor underground hydrant is a specialized firefighting device designed for areas prone to freezing temperatures. Unlike traditional wet barrel hydrants, which store water in the above-ground barrel, dry barrel hydrants keep the water below ground in an underground pipe when not in use. This prevents the water from freezing during cold weather, ensuring the hydrant remains operational in emergencies. The "3-way" designation refers to the hydrant's ability to connect hoses in three directions, facilitating efficient water distribution for firefighting purposes. Installed underground with a ground-level access point, these hydrants are protected from external damage and provide quick access to water when needed, crucially supporting firefighting efforts in urban and suburban environments alike.

 
Advantage Of 3 Way Dry Barrel Outdoor Underground Hydrant
 

Durability

Designed to withstand outdoor conditions and underground installation, these hydrants are built to be robust and resistant to corrosion.

Versatility

The three-way configuration allows multiple hoses to be connected simultaneously, enhancing firefighting efficiency by distributing water to different points.

Reliability

Dry barrel hydrants are less prone to freezing in colder climates compared to wet barrel hydrants, as water drains from the barrel when not in use.

Safety

They are designed with safety features to prevent accidental activation and to ensure reliable operation when needed.

Types Of Dry Barrel Outdoor Underground Hydrant 

-0111

Standard Dry Barrel Hydrants

These are the most common types used in urban and suburban areas. They typically have a single outlet and are designed for general firefighting purposes.

201507300829528414011

Extended Reach Hydrants

These hydrants have longer stems or outlets, allowing firefighters to access water in deeper or hard-to-reach areas, such as along highways or in industrial settings.

2020245583042111

High-Pressure Hydrants

Designed to handle higher water pressures, these hydrants are used in areas where water pressure requirements are elevated, ensuring adequate flow during firefighting operations.

Components Of 3 Way Dry Barrel Outdoor Underground Hydrant

 

Barrel Assembly

This is the main body of the hydrant that houses the operating mechanism and valve assemblies. It is usually made of durable materials such as ductile iron to withstand underground conditions.

Operating Nut

Located at the top of the hydrant, the operating nut is used to open and close the valve, allowing water flow through the hydrant.

Valve Stem

Connected to the operating nut, the valve stem extends down into the barrel assembly to control the opening and closing of the hydrant valve.

Valve Seat

The valve seat is where the hydrant valve rests when closed, preventing water flow. It forms a seal to prevent leaks when the hydrant is not in use.

Nozzle Outlets

A 3-way hydrant typically has three nozzle outlets (ports) where hoses can be connected. These outlets allow firefighters to distribute water to multiple points simultaneously.

Drain Valve

Located near the base of the hydrant, the drain valve allows for draining of water from the barrel assembly to prevent freezing and to facilitate maintenance.

Applications Of 3 Way Dry Barrel Outdoor Underground Hydrant 

-0111

Fire Protection

Primary use is for firefighting purposes, providing quick access to water for extinguishing fires in urban, suburban, and industrial areas.

201507300829528414011

Industrial Facilities

Used in industrial complexes, factories, and manufacturing plants where there is a need for reliable and accessible water supply for fire suppression systems.

2020245583042111

Commercial Buildings

Installed near commercial buildings, shopping centers, and hotels to ensure adequate fire protection coverage.

1394990711

Public Spaces

Placed in parks, recreational areas, and public facilities to safeguard against fire emergencies and protect public safety.

-0111

High-Risk Areas

Deployed in areas with high fire risk, such as airports, fueling stations, chemical plants, and storage facilities, where firefighting capabilities are critical.

201507300829528414011

Urban Infrastructure

Integrated into city water distribution systems to supplement municipal fire departments' efforts in firefighting and disaster response.

 
Material Of 3 Way Dry Barrel Outdoor Underground Hydrant
 

Cast Iron

This is a common material for the barrel assembly and other structural components due to its strength, durability, and resistance to corrosion. Ductile iron can withstand underground installation and exposure to moisture without compromising its structural integrity.

Bronze

Bronze is often used for internal components such as valve seats, stems, and operating mechanisms. It is corrosion-resistant and provides smooth operation of the hydrant valve over its lifespan.

Brass

Brass may also be used for certain components due to its corrosion resistance and ease of machining, though it is less common in underground hydrants compared to bronze.

Polymer Coatings

Some hydrants may have polymer coatings or linings on internal surfaces to further protect against corrosion and extend their operational life.

Specification

Code No.

Outlet

Inlet

XH-FF-01-05

2*(2-1/2'')Male Thread With Cap And Chain+1*4'' BSP Pumper Connection

4'' PN16 BS4504

XH-FF-01-06

2*(2-1/2'')Straight Through Landing Vavle With Cap And Chain+1*4'' BSP Pumper Thread With Cap And Chain

6'' PN16 BS4504

 

How Do 3 Way Dry Barrel Outdoor Underground Hydrant Work

The hydrant's barrel assembly, typically made of durable materials like ductile iron, houses the main components. At the top of the hydrant, there is an operating nut that controls a valve inside the barrel assembly. Turning the operating nut opens or closes the valve, regulating the flow of water. The hydrant usually has three nozzle outlets (ports) where hoses can be connected. When the operating nut is turned to open the valve, water flows from the underground supply through the hydrant and out through the connected hoses. This design allows firefighters to distribute water to multiple points simultaneously, enhancing firefighting efficiency during emergencies. Additionally, the hydrant is equipped with a drain valve near the base to prevent freezing and facilitate maintenance by allowing water to be drained when the hydrant is not in use. These features make the 3-way dry barrel outdoor underground hydrant essential for reliable and accessible water supply in firefighting operations across various environments.

-0111
 
What Training Is Required For The Personnel Operating 3 Way Dry Barrel Outdoor Underground Hydrant

 

-0111

Understanding Hydrant Components and Functionality

Hydrant Anatomy: Training on the different parts of the hydrant, including the barrel, stem, valve, and outlets.

Operational Mechanism: How the dry barrel hydrant operates, focusing on the function of the dry barrel design which prevents water from freezing in the barrel.

201507300829528414011

Operational Training

Opening and Closing the Hydrant: Proper techniques for opening and closing the hydrant to prevent damage.

Flow Testing: Conducting flow tests to measure water pressure and flow rates.

Hydrant Usage in Firefighting: Specific training for firefighters on how to connect hoses and operate the hydrant under emergency conditions.

2020245583042111

Practical Hands-On Training

Field Training: On-the-job training to gain practical experience under the supervision of experienced personnel.

Simulations and Drills: Participating in simulated scenarios and drills to practice response and operational skills.

 

Our Factory

Founded in 2016, Xinhao Fire has rapidly become a prominent player in the fire safety sector, renowned for its premium fire extinguishers and related equipment. Our extensive range of products meets rigorous quality standards, ensuring reliable fire protection. We proudly maintain the esteemed CE0036 certification, demonstrating our unwavering commitment to excellence. Furthermore, our manufacturing processes adhere strictly to the rigorous German TUV ISO9001:2008 standards, highlighting our superior quality management practices.

Our product portfolio includes a diverse selection of fire extinguishers such as dry powder (ABC), carbon dioxide (CO2), foam, and water variants, designed to meet various fire suppression needs.

IMG330111
IMG321811
IMG323511
IMG325611
IMG321311
Certificate

ZHENG

FAQ

 

Q1: What is a 3-Way Dry Barrel Outdoor Underground Hydrant?

A1: It is a type of fire hydrant designed for use in cold climates where the water in the barrel remains underground to prevent freezing, and it has three outlets for hose connections.

 

Q2: How does a dry barrel hydrant differ from a wet barrel hydrant?

A2: In a dry barrel hydrant, the water is kept below ground level to prevent freezing, whereas in a wet barrel hydrant, the water is always present in the barrel above ground.

 

Q3: What are the three outlets on a 3-way hydrant used for?

A3: The three outlets are used to connect multiple hoses simultaneously, allowing for greater flexibility and water distribution during firefighting.

 

Q4: Why is it important for a hydrant to be underground in cold climates?

A4: Being underground protects the hydrant from freezing, ensuring it remains functional during winter months.

 

 

 

 

 

Hot Tags: 3 way dry barrel outdoor underground hydrant, China, manufacturers, suppliers, factory, custom, price, for sale

Send Inquiry